TBC-AP replace to LEM LA-P

TBC-AP系列闭环型霍尔电流传感器(完全代替LEM LA-P系列: LA25-P, LA55-P, LA100-P, LA125-P, LA200-P/SP1)

TBC-AP Series Closed Loop Mode Hall Effect Current Sensor (Replace LEM LA-P Series: LA25-P, LA55-P, LA100-P, LA125-P, LA200-P/SP1)


TBC-AP系列闭环型霍尔电流传感器的初、次级之间是绝缘的,可用于测量直流、交流和脉冲电流。

The TBC-AP series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.

电参数 Electrical data( Ta= 25 ℃ ± 5 ℃ )

型号 Type
参数 Parameter

TBC025AP

TBC50AP

TBC100AP

TBC125AP

TBC200AP

单位
Unit

额定输入电流( Ipn )
Rated input ( Ipn )

25

50

100

125

200

A

测量电流范围( Ip )
Measure range ( Ip )

75 (± 18V ,
180 Ω)

150 (± 18V ,
80 Ω)

300( ± 18V ,
68 Ω )

375( ± 18V ,
15 Ω )

600( ± 18V ,
10 Ω )

A

匝 比 (Np/Ns)
Turnsratio (Np/Ns)

1:1000

1:1000

1:2000

1:1000

1:2000

 

次级线圈电阻
Coil resister

45.00

30.00

45.00

30.00

45.00

Ω

额定输出电流( Is )
Rated output ( Is )

25 ± 0.5%

50 ± 0.5%

50 ± 0.5%

125 ± 0.5%

100 ± 0.5%

mA

电源电压
Supply voltage

± 12 ~± 18

V

功耗电流
Power consumption

20+Ip X(Np/Ns)

mA

失调电流
offset current

@Ip=0 ≤± 0.2

mA

失调电流温漂
Offset current drift

@ -40 ~ +85 ℃ ≤± 0.5

mA

线性度
Linearity

@Ip=0- ± Ipn ≤ 0.1

%FS

带宽
Bandwidth

@ -3dB 0 ~ 200

KHz

响应时间
Response time

@100A/ μ S,10%-90% ≤ 1

µs

绝缘电压
Galvanic isolation

@ 50HZ,1min 3.0

KV