TBC- BA/BS/BR 系列闭环型霍尔电流传感器
TBC- BA/BS/BR Series Closed Loop Mode Hall Effect Current Sensor
TBC-BA/BS/BR 系列闭环型霍尔电流传感器的初、次级之间是绝缘的,可用于测量直流、交流和脉冲电流。
The TBC-BA/BS/BR series current sensor is a closed loop device based on the measuring principle of the hall effect and null balance method, with a galvanic isolation between primary and secondary circuit. It provides accurate electronic measurement of DC, AC or pulsed currents.
电参数 Electrical data( Ta= 25 ℃ ± 5 ℃ )
|
型号 Type 参数 Parameter
|
TBC50BA/BS/BR
|
TBC100BA/BS/BR
|
TBC200BA/BS/BR
|
TBC300BA/BS/BR
|
TBC400BA/BS/BR
|
单位 Unit
|
额定输入电流 (Ipn) Rated input (Ipn)
|
50
|
100
|
200
|
300
|
400
|
A
|
测量电流范围 (Ip) Measure range (Ip)
|
150 (±18V,90Ω)
|
300(±18V,30Ω)
|
600(±18V,30Ω)
|
900(±18V,15Ω)
|
1200(±18V,2Ω)
|
A
|
匝 比 (Np/Ns) Turns ratio (Np/Ns)
|
1:1000
|
1:1000
|
1:2000
|
1:3000
|
1 : 4000
|
T
|
额定输出电流 (Isn) Rated output(Isn)
|
50 ± 0.5%
|
100 ± 0.5%
|
100 ± 0.5%
|
100 ± 0.5%
|
100 ± 0.5%
|
mA
|
线圈内阻 @ 70 ℃ Coil resister @ 70 ℃
|
20
|
20
|
25
|
40
|
54
|
Ω
|
测量电阻 Measure resister
|
2 ~ 50
|
Ω
|
电源电压 Supply voltage
|
± 12 ~± 18
|
V
|
功耗电流 Power consumption
|
≤ 20+IpX (Np/Ns)
|
mA
|
失调电流 Zero offset
|
@Ip=0 ≤± 0.15
|
mA
|
零点温漂 Zero drift
|
@ -40 ~ +85 ℃ ≤± 0.4
|
mA
|
线性度 Linearity
|
@Ip=0- ± Ipn ≤ 0.1
|
%FS
|
带宽 Bandwidth
|
@ -1dB 0 ~ 150
|
KHz
|
响应时间 Response time
|
@100A/ μ S,10%-90% ≤ 1
|
μS
|
绝缘电压 Galvanic isolation
|
@ 50HZ,AC,1min 3
|
KV
|